본문 바로가기 주메뉴 바로가기

ATE System

RCDS-750V / 1000V / 1500V / 2000V

Model :
RCDS-750V / 1000V / 1500V / 2000V

OVERVIEW


Applied in the testing and quality control of lithium battery modules & packs such as new energy vehicles, energy storage base stations, and can realize the integration of charging and discharging data monitoring.


ADVANTAGES


  • Support single battery voltage consistence test
  • Support multi-channel parallel
  • Power factor value up to 0.99
  • Anti-reverse connection and data protection
  • Battery discharge and energy feedback efficiency ≥96%
  • Three-level technology,wide voltage output, small current ripple
  • Support RS485/CAN battery pack communication protocol, CAN communication baud rate is changeable
  • Support DBC import at one-click
  • Support user-defined BMS values as control/protection parameters
  • Support slope charging and discharging
  • User-defined login management rights are supported
  • National standard plug, simulate charging pile for charging(optional)


FUNCTION TEST


  • Cycle life test
  • Battery capacity test
  • Charge retention test
  • Static / dynamic SOC test
  • Charging / discharging test
  • Temperature characteristic test
  • High-speed working condition pulse test
  • DCIR test


specification


Models
RCDS-750V / 1000V / 1500V / 2000V 
AC ParametersWiring methodThree-phase five-wire system
Power supply voltage380±10% VAC
Power supply frequency50±5% Hz
Power factor> 0.99
Max. power feedback efficiency≥ 96%
THD< 3%
DC ParametersOutput current200A / 300A / 400A / 500A / 600A / 1000A
Single channel voltage range750V~1500V...2000V
Voltage accuracy± 0.05%F.S
Voltage resolution1mV
Current accuracy± 0.05% F.S
Current resolution1mA
Current start response time5ms (10%~90% F.S)
Current switching time10ms (~90%~90% F.S)
Min. Working Condition Simulation Interval20ms
Charging modeCC, CV, CP, Slope etc.
Discharge modeCC, CV, CP, CR, Slope etc.
Other working modeStill, Working condition test, Pulse test, DCIR etc.
Test cut-off conditionBattery voltage, current, time, capacity, temperature
Upper computer
software function
Data export formatExcel, TXT etc.
Data recording interval10ms
Editable stepMax. 10000
Programmable stepMax. 10000
Nested loopMax. 10 layers
Software protectionOCP/OVP/UVP/Reverse or wrong connection protection/
Protection for abnormal communication
Third-party device integrationSupports linkage of temperature box, MTV/MTS, and I/O control box, and chiller
Other parametersIP gradeIP20
Working temperature0℃~40℃
Cooling methodForced Fan-cooled
Noise< 75dB
Cabinet size (W*D*H mm)(1600~2800)*1100*2000
TOP 스마트스토어 032-541-2371