OVERVIEW
Applied in Li-ion battery, lead acid battery, nickel-cadmium battery testing and quality control, can realize the integration of charge and discharge data monitoring.
ADVANTAGES
FUNCTION TEST
specification
Models | HRCDS-5V / 10V | |
AC parameters | Wiring method | Three-phase five-wire system |
Power supply voltage | 380±10% VAC | |
Power supply frequency | 50±5% Hz | |
Power factor | > 0.99 | |
Max. power feedback efficiency | ≥ 75% | |
THD | < 5% | |
DC parameters | Output current | 30A / 60A / 100A / 150A / 300A |
Single channel voltage range | 0.8V ~ 5V | |
Voltage accuracy | ± 0.02% F.S | |
Voltage resolution | 0.1mV | |
Current accuracy | ± 0.02% F.S | |
Current resolution | 0.1mA | |
Current start response time | 5ms (10% ~ 90% F.S) | |
Current switching time | 10ms (~90% ~ 90% F.S) | |
Min. Working Condition Simulation interval | 10ms | |
Upper computer software function | Charging mode | CC, CV, CCCV, CP etc. |
Discharge mode | CC, CV, CR, CP etc. | |
Other working mode | Still/Pause, Working condition test, Pulse test, DCIR | |
Test cut-off condition | Battery voltage, current, time, capacity, temperature | |
Data export format | Excel, TXT etc. | |
Data recording interval | 10ms | |
Editable step | Max. 10000 | |
Programmable step | Max. 10000 | |
Nested loop | Max. 10 layers | |
Software protection | OCP/OVP/UVP/Reverse or wrong connection protection/ Protection for Abnormal consumption | |
Third-party device integration | Supports linkage of temperature box, MTV/MTS, and pressure sensor | |
Other parameters | IP grade | IP20 |
Working temperature | 0°C ~ 40°C | |
Cooling method | Forced Fan-cooled | |
Noise | < 75dB | |
Cabinet size (W*D*H mm) | 600 * 850 * 1030 / 600 * 800 * 1980 |